6V-AGM Dual-Purpose AGM
Capacity Minutes Capacity Amp-Hours Energy (kWh) Dimensions inches (mm) Weight lbs. (kg)
 

 

@25 Amps
385

 

5-Hr Rate

154
10-Hr Rate
184
20-Hr Rate
200
100-Hr Rate
221

 

1.33

Length
10.28 (261)
Width
7.08 (180)
Height
10.74 (273)
65 (29)

 
  • Marine batteries feature handles for easy lifting in tight spaces and dual marine terminals to hookup all your electronic gear
  • Trojan's proprietary Maxguard® Advanced Design Separator and exclusive Alpha Plus® paste formulation team up to increase battery life, extend run time and decrease maintenance
  • Outstanding technical support is available on the phone or on the web 
  •  
    Price is with a like core exchanged at time of delivery. Core cost is $30.00 with out a core to exchange


    PLEASE NOTE:
    SOME BATTERIES ARE NOT STOCK AT EVERY WAREHOUSE LOCATION.
     
     PLEASE CALL US @ 888-737-5681
     PRIOR TO PLACING YOUR ORDER SO WE CAN MAKE SURE THE BATTERY YOU ARE ORDERING IS IN STOCK AT THE NEAREST WAREHOUSE TO YOUR LOCATION.
     
     THIS WILL INSURE PROMPT DELIVERY TO YOUR LOCATION

     

     

    USA Battery Sales can supply Trojan Batteries
     for all you battery needs: 
     Truck, Golf Car, RV's. Marine , Solar & Wind Energy Storage.
     
     
    Trojan Battery Type Cap. (min.) Cap. (min.) Cranking Performance 5 Hr rate 20 Hr rate Terminal Config. Dim. Inches rounded Wt. lbs
    @25A @75A

    CCA@

    0 F.

    CA@

    32 F.

    AH AH See below L W

    Ht

    f.

    RENEWABLE ENERGY SERIES DEEP CYCLE - 6 & 2 Volt
    L16RE-A     - -   325 1 11.6 7 17.7 115
    L16RE-B     - -   370 1 11.6 7 17.7 118
    L16RE-2V     - -   1110 1 11.6 7 17.7 119
    T105-RE     - -   225 1 10.4 7.1 11.8 67
    DEEP CYCLE - 6 VOLT
    T-605 383 105 - - 175 210 2,6,11 10.4 7.1 10.9 58
    T-105 447 115 - - 185 225 1,2,6,11 10.4 7.1 10.9 62
    T-125 488 132 - - 195 240 2,6,11 10.4 7.1 10.9 66
    T-145 530 145 - - 215 260 2,6,11 10.4 7.1 11.6 72
    TE35 500 135 - - 200 245 2 9.6 7.5 10.9 68
    J250G 475 130 - - 195 235 11 11.6 7 11.9 67
    J250P 540 135 - - 215 250 7 11.6 7 11.5 72
    J305E-AC 645 160 - - 250 305 11 12.3 7 14.4 83
    J305G-AC 678 175 - - 255 310 11 12.3 7 14.4 88
    J305P-AC 711 195 - - 270 315 7 11.6 7 14.4 96
    J305H-AC 781 215 - - 285 335 7 11.6 7 14.4 98
    L16E-AC 766 185 - - 303 370 11 12.3 7 17 100
    L16G-AC 789 200 - - 320 390 11 12.3 7 17 107
    L16P-AC 850 220 - - 344 420 7 11.6 7 16.8 114
    L16H-AC 935 245 - - 357 435 7 11.6 7 16.8 125
    DEEP CYCLE - 8 VOLT
    T-860 - g - - 125 150 6 10.4 7.1 10.9 56
    T-875 295 h - - 145 170 2,6,11 10.4 7.1 10.9 63
    T-890 340 i - - 155 190 2,6,11 10.4 7.1 10.9 69
    DEEP CYCLE - 12 VOLT
    24TMS 125 34 470 575 62 72   11.3 8.8 9.8  
    24TM 135 34 550 675 66 85   11.3 8.8 9.8  
    24TMX 140 36 440 540 70 85 12 11.3 6.8 9.8 47
    27TMS 175 45 530 650 85 105 12 12.8 6.8 9.8 55
    27TM 175 45 530 650 85 105 12 12.8 6.8 9.8 55
    27TMX 175 45 530 650 85 105 12 12.8 6.8 9.8 55
    27TMH 200 51 620 760 95 115 2,11,12 12.8 6.8 9.8 59
    30XHS 225 57 665 820 105 130 2,11,12 13.4 6.8 9.8 66
    31XHS 225 57 665 820 105 130 10 13 6.8 9.5 67
    J150 280 70 - - 125 150 14 13.8 7.1 11.1 84
    T-1260 260 90 - - 113 140 2,6 12.9 7.1 10.7 78
    T-1275 280 102 - - 120 150 2,6 12.9 7.1 10.9 82
    J185E-AC 312 82 - - 144 175 11 15.5 7 14.6 102
    J185G-AC 300 85 - - 150 180 11 15.5 7 14.6 106
    J185P-AC 375 95 - - 160 195 7 15 7 14.6 114
    J185H-AC 415 110 - - 180 215 7 15 7 14.6 128
    DC-500ML 1050 272 - - 361 450 1,2 19.3 10.6 16.8 332
    DEEP CYCLE - 36 VOLT
    18DC-500ML 1050 272 - - 361 450 5 35.3 19.1 16.8 986
    DEEP CYCLE GEL - 12 VOLT
    24-GEL 147 - 330 460 66 77 7,11 10.8 6.8 9.3 52
    27-GEL 179 - 395 545 76 91 11 12.9 6.8 9.3 63
    31-GEL 200 - 445 620 85 102 11 12.9 6.8 9.6 69
    DEEP CYCLE GEL - 6 VOLT
    6V-GEL 394 - 575 825 154 189 11 10.3 7.1 10.8 68
    OUTDOOR (AGM) DUAL PURPOSE STARTING/DEEP CYCLE - 12 VOLT
    24-AGM 130 - 440 620 61 80 11 10.9 6.7 8.2 52
    27-AGM 175 - 560 780 76 99 11 12 6.7 8.2 66
    31-AGM 190 - 720 950 83 110 11 13.1 6.9 8.4 71
    4D-AGM 325 - 1110 1420 131 165 11 20.8 8.3 8.5 115
    8D-AGM 460 - 1450 1850 179 230 11 20.5 10.6 8 155
    OUTDOOR (AGM) DUAL PURPOSE STARTING/DEEP CYCLE - 6 VOLT
    6V-AGM 380 - 1100 1400 142 180 11 10.3 7.1 10.8 58
    SUPERIOR CYCLING SERIES SCS - OUTDOOR DEEP CYCLE - 12 VOLT
    SCS150 150 36 530 650 80 100 8 11.3 6.8 9.8 50
    SCS200 200 52 620 760 95 115 8 12.8 6.8 9.8 60
    SCS225 225 57 665 820 105 130 8 13.9 6.8 9.8 66
    OUTDOOR STARTING - 12 VOLT
    24SM-650 85 - 520 635 - - 12 11.3 6.8 9.8 38
    24SM-850 125 - 700 860 - - 12 11.3 6.8 9.8 43
    24SM-1000
    160
    - 740 905 - - 8 11.3 6.8 9.8 49
    27SM-1100
    205
    - 860 1050     13 12.8 6.8 9.8 55
    OUTDOOR MAINTENANCE-FREE STARTING - 12 VOLT
    24SM-850MF 125 - 700 860 - - 12 11.3 6.8 9.8 43
    24SM-1000MF
    160
    - 740 905 - - 8 11.3 6.8 9.8 49
    Terminal Configurations

    1. "L" terminal (LT)

    2. Automotive post (AP)

    3. Bus terminal (BT)

    4. Button terminal

    5. Cable and Plug

    6. Low profile terminal (LPT)

    7. Dual terminal AP-Stud (DT)

    8. Dual wingnut terminal (DWNT)

    9. Side terminal

    10. Stud terminal

    11. Universal terminal (UT)

    12. Wingnut (WNT)

    13. Marine dual terminal (APW)

    14. High profile terminal (HPT)

    f. Height is measured from the bottom of the battery to the top of the terminal. Heights may vary according to type of terminals specified.

    g. Capacity @ 56 amps is 90 minutes.

    h. Capacity @ 56 amps is 117 minutes.

    i. Capacity @ 56 amps is 132 minutes.

    Note: Specifications are subject to change without notice.